PALETEO.com | Warehouse equipment

Categories

Spill pallet for fuels and diesel: which one and how many litres

Published on: 21-06-2023

For fuels – diesel, petrol – and other flammable liquids a steel spill pallet is chosen, with a capacity at least equal to the largest container: 200 l under a 200 l drum and 1000 l under an IBC. PALETEO steel spill pallets for drums hold 200–214 l with a load capacity from approx. 700 to approx. 1500 kg, and those for IBCs hold 1000–1140 l. For flammable liquid waste the regulations require a larger capacity, and the storage site must meet fire protection requirements.

Table: steel spill pallets for fuels

ModelExternal dimensions [mm]Sump capacityLoad capacity
WWS200PM1220 × 1220 × 280200 lapprox. 700 kg
WWS1TS860 × 860 × 410202 lapprox. 950 kg
WWS2TS1340 × 860 × 320214 lapprox. 1500 kg
WWI1PM (IBC)1300 × 1150 × 7801000 lapprox. 1000 kg
WWS4TS (IBC)1650 × 1350 × 6201140 lapprox. 1366 kg

Data from PALETEO product pages.

What to check

  • Flammable waste. For flammable liquid waste in Poland the greater of two values applies: 25% of the total volume or 110% of the largest container. Rules in other countries differ.
  • Fire protection requirements. Check the conditions for storing flammable liquids at your site – the spill pallet is only one element.

Frequently asked questions (FAQ)

Which spill pallet for a 200 l drum of diesel?

A steel one with a capacity of at least 200 l, for example WWS200PM (200 l, approx. 700 kg) or WWS1TS (202 l, approx. 950 kg).

Can a polyethylene spill pallet be used for fuels?

Steel spill pallets are the standard for flammable liquids. Check whether polyethylene may be used in the safety data sheet and in the fire protection requirements.

Need help choosing or a quote for a larger quantity? Send a quote request – we usually confirm price and lead time the same working day.

See in our shop: spill pallets.

See also in our shop: Spill pallets and containment sumps · Industrial plastic tanks

Full guide: How to choose a spill pallet? Sump capacity, rules and types

Gallery
 wanna-wychwytowa

Other articles

  • Plastic parking grid KP4G 60 x 39.5 cm, load capacity 350 t/m²
    24-11-2026

    Which parking grid should you choose? Load capacity, dimensions and pieces per m²: table

    A parking grid is chosen primarily by the load it has to carry: for foot traffic and gardens, grids with a load capacity of approx. 150 t/m² (2.5–3 cm high) are sufficient; for driveways and car parks for passenger cars – 250–350 t/m² (4 cm high); for heavy traffic and the highest axle loads – 450 t/m² grids or 5 cm high models. Depending on the format, you need 2 to 7 grids per m² – the most popular 50 × 50 cm format means 4 pieces per m².

  • Plastic H1 pallet 120x80: pallet weight 18 kg
    17-11-2026

    How much does a pallet weigh? Euro, plastic and H1 pallet weights: table

    A wooden EPAL Euro pallet measuring 1200 × 800 mm weighs approximately 25 kg. A plastic pallet of the same size weighs, depending on its design, from approx. 4.5 kg (a lightweight open-deck export pallet) to approx. 20 kg (closed-deck, reinforced). A hygienic H1 pallet 120 × 80 weighs 18 kg, and 120 × 100 plastic pallets weigh from approx. 6.5 to 23 kg.

  • IBC heating jacket – 1000 l IBC container protected against frost
    10-11-2026

    IBC tank in winter: how to protect an IBC container from frost

    In winter, an IBC tank (1000 l IBC tote) must above all be protected against its contents freezing – water expands by about 9% when it turns to ice, which can crack the drain valve and damage the bottle. An IBC used for rainwater is best emptied before the frosts. An IBC holding process liquids should be stored in a heated building or wrapped in a thermal insulation jacket and – at sub-zero temperatures – a heating jacket with a thermostat.